Green Goo in Electrical Installations

by | May 18, 2024 | Advice, Solution, Wiring

Green goo is a phenomena sometimes encountered in electrical installations constructed in the late 1960s

Unsightly green slime can occur in switch and socket-outlet boxes. It is understood that this phenomenon is most prevalent where pvc cables manufactured between 1965 and 1971 have been used.

The green slime, or green goo, is degraded di-isoctyl phthalate and is considered to result from a chemical reaction between the plasticiser of the insulation and the copper conductor in the pvc cable. Between 1965 and 1971 the temperature performance of pvc was uprated by the inclusion of an anti-oxidant into the pvc compound. An unappreciative side effect was that the anti-oxidant encouraged production of the green goo.

Solution

Unfortunately, where an installation is seriously affected by the deficiency, the only practicable solution is to rewire the premsies and replace any damaged electrical equipment.

There are possible Health and Safety issues of retaining, working with and the disposal of contaminated wiring and accessories. Deposits of the product must not be permitted to be exposed for causal contact, particularly in areas accessible to children.

In cases where a property is to be completely rewired, redundant materials should be disconnected and removed from site. Di-isoctyl phthalate is a toxic substance and suitable protective clothing should be worn when handling waste materials. Special attention should be paid to hygiene when working on contaminated installations. Waste should be disposed of in suitable labelled containers and to registered Waste Disposal Contractors. NICEIC strongly recommends that advice is sought from the Health and Safety Executive as to appropriate action when dealing with installations so affected.

Due to Green Goo in Electrical Installations being hazardous, Goodwin Electrical in Plymouth recommend a rewire. Contact us now on 01752 916047 or fill in our Contact Form.

Related Posts

Latest Projects

Ventilation Improvements

Ventilation Improvements

ProjectThe DetailsThe Challenge Rectify damp and condensation problems in a property with solid brick walls.The Solution Supply and install DMEV centrifugal ventilation fan in bathroom. Core drill wall in kitchen and install ducting to extract out from cooker hood....

Solar Panel Installation

Solar Panel Installation

ProjectThe DetailsThe Challenge Design and Install a 3.6kW Solar PV system for a property in Plymstock, Plymouth. This work involved a difficult scaffold setup and also obtaining materials on the nominated day.The Solution Desin the Solar PV system with PV sole and...

Outlet Failure Repairs

Outlet Failure Repairs

ProjectThe DetailsThe Challenge Vivamus ipsum velit, ullamcorper quis nibh non, molestie tempus sapien. Mauris ultrices, felis ut eleifend auctor, leo felis vehicula quam, ut accumsan augue nunc at nisl. Vivamus ipsum velit, ullamcorper quis nibh non, molestie tempus...

Efficient Lighting System

Efficient Lighting System

ProjectThe DetailsThe Challenge Vivamus ipsum velit, ullamcorper quis nibh non, molestie tempus sapien. Mauris ultrices, felis ut eleifend auctor, leo felis vehicula quam, ut accumsan augue nunc at nisl. Vivamus ipsum velit, ullamcorper quis nibh non, molestie tempus...